​​​​​​​​Oils 7600 Homogenizing AutosamplerOne Autosampler for both oils and coolants

Oils testing laboratories are adding more sample types as their industry becomes more complex. The Oils 7​​600 Homogenizing Autosampler allows two sample matricies to be introduced to an ICP instrument from the same system. Boasting a dual port rinse station fed by two separate peristaltic pumps, it can change between oils and coolants testing on demand. With improved speed, mixing capability and sample drip capture, the Oils 7600 delivers robust analysis without compromise.​

Sample Homogenization

Used oil samples typically contain particulate material that can settle in a sample tube prior to analysis; this can lead to generation of non‑representative data. The Oils 7600 automation has been designed to resolve this problem. 

Prior to analytical measurement, each sample is homogenized by the autosampler. A stirring paddle mounted next to the sample probe efficiently mixes each sample and, with the sample probe, is cleaned at the rinse station. Sample mixing is configurable, via a software dashboard, to meet the challenge of more viscous oil samples​.​



Faster

Faster an​​d smoother XYZ movement saves up to 2 seconds per sample compared to previous generation oils automation. Analyze 2 samples per minute with the ASXPRESS PLUS rapid sample introduction for ASTM 5185 and ASTM 6130 testing.​

​Improved Accuracy

Superior motion control with the 7000 Series automation platform allows more accurate and precise XYZ movement for robust sample analysis.​

Cleaner

An improved drip cup allows sample drip capture and retention to eliminate cross contamination at faster XYZ movement. An integrated dual port rinse station helps minimize analyte carryover and cross contamination.​

New Drip Cup Design​

An improved drip cup design captures and retains any sample droplets, eliminating cross contamination while the probe and stirrer move over the sample tubes. The new design uses a cam shaft to provide smoother movement and also has and an internal lip to ensure liquid retention while moving at higher speeds.​

Dual Rinse Station​

Used oil and coolant samples can be analyzed from the same automation with a sliding rinse station. For oils testing, the probe and stirrer are rinsed in ports fed from a peristaltic pump with kerosene or white spirit. For coolants testing, the rinse station slides over and engages a second peristaltic pump that delivers an appropriate rinse agent such as water or nitric acid. By changing the sample probe, stirring paddle and ICP glassware, the analyst can switch from oils testing to coolants testing within 5 minutes.​​

 Video

 Specs

Specification Title​ Specification Details
Dimensions
     ​Height 49 cm (19.3 in)
     ​Width 81 cm (31.9 in) 
     ​Depth 57.5 cm (22.7 in)​​
     ​Weight 35 kg (77 lbs)​
Oils 7600 Capacity Up to 6 racks, up to 576​ samples
Rack Options Gilson, Bel-Art, CETAC/Bohdan, Janus
Customized racks available
Hardware Interfaces RS-232 and USB
Power Requirements 100-240 VAC, 47-63 Hz, 1.9 A
Minimum Computer Requirements Windows 7 or higher
2 Free COM or USB ports
Adobe® Acrobat® Reader is required
to read the manuals that accompany the
software
Internet Explorer 6 or higher must be
installed for system to function properly


 Application Notes

  
  
TN-OILS7400-001.pdfGilson Rack Compatibility For Oils 7400 and Oils 7600 Homogenizing Autosamplers
AP-SimPrep-004.pdfAutomated Sample Preparation of Coolant Samples for Analysis by ICP-OES
AP-Oils7000-001.pdfAnalysis of Lubricating Oils following ASTM D5185
AP-Oils7000-002.pdfUsing Automated Sample Mixing to Improve the Quality of Engine Oils Analysis with ICP-OES

 Contact Us

​​Contact us using an​y of the methods below for more information on this or other Teledyne CETAC products.

Email: [email protected]

Toll Free: 1-800-369-2822

International: +1 402-733-2829​​

​​​​​​​​